1993, ISBN: 079238833X
[EAN: 9780792388333], Neubuch, [PU: Springer Netherlands Dez 1993], NEURO.; NEUROLOGIE / NEUROLOGIE; SURGERY; TRANSCRANIALMAGNETICSTIMULATION; CORTEX; NEUROSURGERY; PERCEPTION, This item … Mehr…
AbeBooks.de BuchWeltWeit Inh. Ludwig Meier e.K., Bergisch Gladbach, Germany [57449362] [Rating: 5 (von 5)] NEW BOOK. Versandkosten:Versandkostenfrei. (EUR 0.00) Details... |
1993, ISBN: 9780792388333
Springer, Gebundene Ausgabe, Auflage: 1994, 467 Seiten, Publiziert: 1993-12-31T00:00:01Z, Produktgruppe: Buch, 4.06 kg, Neurochirurgie, Chirurgie, Medizin, Kategorien, Bücher, Neurobiolog… Mehr…
amazon.de -PBShop UK- Versandkosten:Gewöhnlich versandfertig in 4 bis 5 Tagen. Die angegebenen Versandkosten können von den tatsächlichen Kosten abweichen. (EUR 3.00) Details... |
1993, ISBN: 9780792388333
Editor: Jones, S.J. Editor: Boyd, S. Editor: Hetreed, M. Editor: Smith, N.J. Springer, Hardcover, Auflage: 1994, 467 Seiten, Publiziert: 1993-12-31T00:00:01Z, Produktgruppe: Book, 1.84 kg… Mehr…
amazon.com Amazon.com Versandkosten:Usually ships within 2 to 3 days. Lieferung von Amazon., zzgl. Versandkosten Details... |
Handbook of Spinal Cord Monitoring Proceedings of the Fifth International Symposium on Spinal Cord Monitoring, London, UK, June 2¿5, 1992 - gebunden oder broschiert
1993, ISBN: 079238833X
1994 Gebundene Ausgabe Neuro..., Neurologie / Neuro..., Neurologie, Neurologie und klinische Neurophysiologie, surgery; TranscranialMagneticStimulation; Cortex; neurosurgery; Perception… Mehr…
Achtung-Buecher.de MARZIES.de Buch- und Medienhandel, 14621 Schönwalde-Glien Versandkosten:Versandkostenfrei innerhalb der BRD. (EUR 0.00) Details... |
Handbook of Spinal Cord Monitoring Proceedings of the Fifth International Symposium on Spinal Cord Monitoring, London, UK, June 2¿5, 1992 - gebunden oder broschiert
1993, ISBN: 079238833X
1994 Gebundene Ausgabe Neuro..., Neurologie / Neuro..., Neurologie, Neurologie und klinische Neurophysiologie, surgery; TranscranialMagneticStimulation; Cortex; neurosurgery; Perception… Mehr…
Achtung-Buecher.de MARZIES.de Buch- und Medienhandel, 14621 Schönwalde-Glien Versandkosten:Sans frais d'envoi en Allemagne. (EUR 0.00) Details... |
1993, ISBN: 079238833X
[EAN: 9780792388333], Neubuch, [PU: Springer Netherlands Dez 1993], NEURO.; NEUROLOGIE / NEUROLOGIE; SURGERY; TRANSCRANIALMAGNETICSTIMULATION; CORTEX; NEUROSURGERY; PERCEPTION, This item … Mehr…
1993, ISBN: 9780792388333
Springer, Gebundene Ausgabe, Auflage: 1994, 467 Seiten, Publiziert: 1993-12-31T00:00:01Z, Produktgruppe: Buch, 4.06 kg, Neurochirurgie, Chirurgie, Medizin, Kategorien, Bücher, Neurobiolog… Mehr…
1993
ISBN: 9780792388333
Editor: Jones, S.J. Editor: Boyd, S. Editor: Hetreed, M. Editor: Smith, N.J. Springer, Hardcover, Auflage: 1994, 467 Seiten, Publiziert: 1993-12-31T00:00:01Z, Produktgruppe: Book, 1.84 kg… Mehr…
Handbook of Spinal Cord Monitoring Proceedings of the Fifth International Symposium on Spinal Cord Monitoring, London, UK, June 2¿5, 1992 - gebunden oder broschiert
1993, ISBN: 079238833X
1994 Gebundene Ausgabe Neuro..., Neurologie / Neuro..., Neurologie, Neurologie und klinische Neurophysiologie, surgery; TranscranialMagneticStimulation; Cortex; neurosurgery; Perception… Mehr…
Handbook of Spinal Cord Monitoring Proceedings of the Fifth International Symposium on Spinal Cord Monitoring, London, UK, June 2¿5, 1992 - gebunden oder broschiert
1993, ISBN: 079238833X
1994 Gebundene Ausgabe Neuro..., Neurologie / Neuro..., Neurologie, Neurologie und klinische Neurophysiologie, surgery; TranscranialMagneticStimulation; Cortex; neurosurgery; Perception… Mehr…
Bibliographische Daten des bestpassenden Buches
Autor: | |
Titel: | |
ISBN-Nummer: |
Detailangaben zum Buch - Handbook of Spinal Cord Monitoring: Proceedings of the Fifth International Symposium on Spinal Cord Monitoring, London, UK, June 2?5, 1992
EAN (ISBN-13): 9780792388333
ISBN (ISBN-10): 079238833X
Gebundene Ausgabe
Erscheinungsjahr: 1994
Herausgeber: Springer
472 Seiten
Gewicht: 0,865 kg
Sprache: eng/Englisch
Buch in der Datenbank seit 2008-04-29T14:50:40+02:00 (Vienna)
Detailseite zuletzt geändert am 2023-11-28T17:08:46+01:00 (Vienna)
ISBN/EAN: 9780792388333
ISBN - alternative Schreibweisen:
0-7923-8833-X, 978-0-7923-8833-3
Alternative Schreibweisen und verwandte Suchbegriffe:
Autor des Buches: boyd smith, jones
Titel des Buches: monitoring, spinal cord, international proceedings, symposium, handbook london, proceedings june 1992, the cord
Daten vom Verlag:
Autor/in: S.J. Jones; S. Boyd; M. Hetreed; N.J. Smith
Titel: Handbook of Spinal Cord Monitoring - Proceedings of the Fifth International Symposium on Spinal Cord Monitoring, London, UK, June 2–5, 1992
Verlag: Springer; Springer Netherland
450 Seiten
Erscheinungsjahr: 1993-12-31
Dordrecht; NL
Gewicht: 1,840 kg
Sprache: Englisch
213,99 € (DE)
219,99 € (AT)
236,00 CHF (CH)
POD
XVII, 450 p.
BB; Neurology; Hardcover, Softcover / Medizin/Klinische Fächer; Neurologie und klinische Neurophysiologie; Verstehen; Surgery; Transcranial Magnetic Stimulation; cortex; neurosurgery; perception; Neurosciences; Neurology; Neuroscience; Neurowissenschaften; BC; EA
Invited Chapters.- 1 Somatosensory evoked potentials and their use for spinal cord monitoring.- 2 Human spinal cord potentials recorded from the epidural space.- 3 Indications for the use of evoked potentials in spinal surgery — review of the Nottingham experience and current use.- 4 Anaesthetic requirements for spinal surgery and effective cord monitoring.- 5 Application of intraoperative spinal cord monitoring to neurosurgery.- 6 Lessons from spinal cord monitoring.- 7 A multicentre survey of spinal cord monitoring outcome.- 8 Round Table Debate on International Spinal Cord Monitoring Practice.- Present status of spinal cord monitoring in Japan.- Spinal cord monitoring in the UK.- General perception of the usefulness and failings of spinal cord monitoring. The U.C.L. experience.- Somatosensory and spinal cord evoked potential studies in humans.- 9 Spinal cord evoked potentials in cervical and thoracic myelopathy.- 10 Spinal cord evoked potentials in spinal cord intermittent claudication.- 11 Somatosensory cerebral potentials evoked by paraspinal stimulation: an approach to spinal cord monitoring.- 12 The effect of changes in epidural temperature on spinal evoked potentials during scoliosis surgery.- 13 Threatened spinal cord damage due to Luque’s wires.- 14 Comparison of common peroneal and posterior tibial nerve stimulation for routine spinal cord monitoring during surgical correction of scoliosis.- 15 An explanation of the high ‘false-positive’ rate of lower limb SEPs in descending aorta surgery.- 16 Decomposition of spinal cord evoked potentials into propagating and stationary components.- 17 An atlas of human spinal cord evoked potentials.- 18 A multichannel planar epidural electrode for spinal cord monitoring.- 19 Somatosensory evoked potentials (EPs) during anterior and posterior spinal surgery.- 20 Spinal cord monitoring with a new device for automated signal analysis.- 21 Evaluation of peroperative sensory evoked potentials recorded from nerve roots to the cervical epidural space during brachial plexus surgery.- 22 Automated spinal cord monitoring system with multimodal evoked potentials.- 23 Pain-related somatosensory evoked potentials following CO2 laser stimulation in myelopathy.- 24 Level diagnosis of cervical myelopathy using somatosensory evoked potentials.- 25 Spinal cord monitoring during surgery for intramedullary spinal cord tumours.- 26 Graded risk levels of somatosensory evoked potentials during scoliosis surgery.- 27 Intraoperative spinal cord monitoring with spino-spinal evoked potentials.- 28 Monitoring cortical evoked potentials (EPs) in operations on the cervical spine.- 29 A computer simulation of conduction block — conduction block induced augmentation and killed-end potential.- 30 Quantifying the SSEP — the area under the curve.- 31 The effects of propofol and nitrous oxide on median nerve somatosensory evoked potentials during fentanyl anaesthesia.- Studies of the human motor system.- 32 Effects of anaesthesia on the EEG — bispectral analysis correlates with movement.- 33 H-reflex spinal cord monitoring during vertebral column stabilization surgery.- 34 Central motor conduction time to upper versus lower extremities.- 35 Do neurogenic lesions of the spinal cord generate distinctive features of the epidurally recorded motor evoked potential?.- 36 Anaesthesia and the motor evoked potential.- 37 A method to assess the effect of neuromuscular blocking agents on the spinal motor evoked potential during spinal surgery.- 38 Defining reliable anaesthetic protocols for intraoperative monitoring of transcranial magnetic motor evoked potentials.- 39 Transcranial magnetic stimulation for spinal cord monitoring.- 40 Evaluation of motor pathways in patients with cervical myelopathy by magnetic stimulation: pre-, intra-, and postoperative study.- 41 An attempt at noninvasive mapping of the human motor cortex using transcranial magnetic stimulation.- 42 Separation of upper and lower extremity components of the cortico spinal MEP (D-wave) recorded at the cervical level.- 43 Changes in the corticospinal MEP (D-wave) during microsurgical removal of intramedullary spinal cord tumours; experience in 16 cases.- 44 Ketamine anaesthesia allows recording of muscle responses to magnetic cortical stimulation: an electrophysiological study in man.- 45 Long-term and quantitative assessment of spinal cord motor function by motor evoked potentials..- 46 Correlation of clinical, radiological and electrophysiological (MEP) findings in cervical myelopathy.- 47 Recording of myogenic motor evoked potentials (mMEP) under general anaesthesia using a train of transcranial electric stimuli.- 48 Electromyography of paravertebral muscles for evaluation of spinal disorders.- 49 Differential effect of isoflurane on motor evoked potentials elicited by transcortical electric or magnetic stimulation.- 50 Temporal summation and motor evoked potential spinal cord monitoring in man.- 51 Near maximal transcranial magnetic motor evoked potentials during surgery.- 52 Rapid changes in killed-end corticospinal MEP in patients with acute spinal cord injury.- Animal studies.- 53 Electrophysiological phenomena recorded from spinal cord slice preparation in the adult rat.- 54 Transcranial magnetic motor evoked potentials recorded from the spinal cord in cats: normal waves and spinal cord injuries.- 55 In vitro animal study of the spinal cord evoked potentials.- 56 Comparison of spinal evoked potentials by transcranial magnetic and electrical stimulation — a canine study.- 57 Comparison between descending segmental evoked spinal cord potentials and conductive evoked spinal cord potentials under acute spinal cord compression.- 58 Refractory period of motor evoked potentials and spinal cord evoked potentials in the cat.- 59 The effect of anaesthetic agents on descending spinal cord evoked potential and the compound muscle action potentials elicited by stimulation at the motor cortex and the spinal cord.- 60 Acute motor evoked potential changes following spinal cord ischaemia in the rat.- Index of Authors by Chapter Number.Proceedings of the 5th International Symposium, London, June 2--5, 1992
Weitere, andere Bücher, die diesem Buch sehr ähnlich sein könnten:
Neuestes ähnliches Buch:
9789401114165 Handbook of Spinal Cord Monitoring als eBook Download von (John E Sheehy)
< zum Archiv...